| Sign In | Join Free | My insurersguide.com | 
 | 
Description : Continuous Emission Monitoring System for HCl and CO in Waste Incineration Flue Gas (CEMS)
Stock : 1set
MOQ : 1set
Price : USD26000
Payment Terms : T/T
Shipping Method : LCL
product name : online gas analyzer
Range : 0-100 Ppm/Mg/M3
Response Time : Less Than 120s
material : Alloy, Metal, Stainless Steel
Power Supply : 220V ±10%, 50Hz ±1Hz, 5 kVA
Light Path : 760mm
WT Online Gas Monitoring System

1. Basic Design Principle of the WT-400 Analysis System
  The WT-400 Ammonia Analysis System adopts a high-temperature extractive monitoring method, with a laser-based NH₃ analyzer as the core unit. All gas-contacting components are heated and insulated to above 180℃ throughout the sampling path, ensuring stable and accurate NH₃ measurements even under challenging process conditions.
2. Operating Conditions and Requirements
2.1 General Process Conditions
Maximum dust concentration: < 2000 g/Nm³
Flue gas temperature at the sampling point: ≤ 600℃
Sampling point pressure: -15 to 15 MPa
Tar and benzene content: < 10 g/Nm³
Presence of saturated water vapor
2.2 Environmental Conditions
Temperature control cabinet installed outdoors; analyzer unit installed indoors
Ambient temperature: 5–45℃
Relative humidity: 20–85% RH
Atmospheric pressure: 10–106 kPa (depending on site location)
2.3 Utilities and Gas Supply
Power Supply: 220V ±10%, 50Hz ±1Hz; Power consumption: 5 kVA; free from strong electrical interference
Compressed Air: For purging the sampling system to prevent clogging; must be clean, dry, oil-free, with a pressure of 4–7 kg/cm² to ensure effective cleaning
Standard Gas: For system preprocessing, calibration, and performance verification; must meet the specified purity requirements to maintain measurement accuracy
| No. | Standard Gas Compositions | Standard Gas Concentration | Standard Gas Pressure | 
| 1 | N2 | ≥ 99.9999% | 0.5 -10 MPa | 
| 2 | NH3 | 80% of the measurement rage | 0.5 -10 MPa | 
3. Features of the WTKF200 Ammonia Escape Online Monitoring System
Integrated Sampling Probe – Compact, streamlined design with large dust holding capacity; supports dust filtration up to ≤ 100 g/Nm³ without clogging.
High Filtration Precision – Dust filtration accuracy < 0.1 μm.
High Measurement Accuracy – Analysis accuracy of ±1% FS.
Fast Response – Response time (T90) ≤ 30 s.
High Reliability – Mean Time Between Failures (MTBF) > 3 years.
Low Maintenance – Maintenance interval exceeds 1 year.
Distortion-Free Sampling – High-temperature extractive sampling method ensures accurate, representative measurements.
Temperature-Controlled Sampling – High-temperature, constant-temperature design maintains NH₃ measurement accuracy.
Automatic Purging – Built-in automatic cleaning system removes dust and prevents blockages.
Signal Output – 4–20 mA output; control alarm signal NO/NC, 1A/220V.
We offer fully customized gas online monitoring solutions tailored to the customer’s unique requirements and operating environments, ensuring optimal performance and measurement accuracy.
|   | 
| Continuous Emission Monitoring System for Flue Gas HCl Co Waste Incineration CEMS Gas Analyzers Images | 
 KF200 In-situ Laser Gas Analyzer TDLAS For Real-Time Monitoring Of CO NH₃ HCl
                                                                                        
                                                        
                        
                        
                        
                                                            KF200 In-situ Laser Gas Analyzer TDLAS For Real-Time Monitoring Of CO NH₃ HCl
                                                    
                        
                     Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
                                                                                        
                                                        
                        
                        
                        
                                                            Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System
                                                    
                        
                     TDLAS Exdiict6 Tunable Infrared Gas Analyzer IP66 with In Situ Installation
                                                                                    
                        
                        
                        
                                                            TDLAS Exdiict6 Tunable Infrared Gas Analyzer IP66 with In Situ Installation
                                                    
                        
                     Explosion Proof Industrial Laser Gas Analyzer for Hazardous Gas Detection
                                                                                    
                        
                        
                        
                                                            Explosion Proof Industrial Laser Gas Analyzer for Hazardous Gas Detection
                                                    
                        
                     Kf200 TDLAS Gas Analyzer 24VDC Fixed For Continuous Emissions Monitoring
                                                                                    
                        
                        
                        
                                                            Kf200 TDLAS Gas Analyzer 24VDC Fixed For Continuous Emissions Monitoring
                                                    
                        
                     Cross Stack Tunable Diode Laser Analyzer 220V AC Maintenance Free
                                                                                    
                        
                        
                        
                                                            Cross Stack Tunable Diode Laser Analyzer 220V AC Maintenance Free
                                                    
                        
                     Industrial Laser Gas Analyzer Exdiict6 GB Customized For Real Time Monitoring
                                                                                    
                        
                        
                        
                                                            Industrial Laser Gas Analyzer Exdiict6 GB Customized For Real Time Monitoring
                                                    
                        
                     Cross Duct TDLAS Gas Analyzer Explosion Proof Customizable For Online Analyzing
                                                                                    
                        
                        
                        
                                                            Cross Duct TDLAS Gas Analyzer Explosion Proof Customizable For Online Analyzing
                                                    
                        
                     Kf200 220V AC Tunable Diode Laser Analyzer For Industrial Pollution Control
                                                                                    
                        
                        
                        
                                                            Kf200 220V AC Tunable Diode Laser Analyzer For Industrial Pollution Control
                                                    
                        
                     Exibd II CT6 KF200 Laser Gas Analyzer For Flue Gas Monitoring SOx NOx
                                                                                    
                        
                        
                        
                                                            Exibd II CT6 KF200 Laser Gas Analyzer For Flue Gas Monitoring SOx NOx